Access Retrofit Hub
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.
Device €235.90 + installation on site €25.00
Included: the device, mounting, connection and commissioning to the usual extent. Travel costs are quoted to you in advance.
Every site is different. If yours needs more — new cable runs, wall openings, work at height or extra devices — you receive a binding quote before we start. Nothing is charged extra without your approval.
Access Retrofit Hub installation service
We install and configure the Access Retrofit Hub on site and hand it over documented. Installation across Germany by quote — we reply the same working day.
- VLANs for office, guests, phones and cameras
- Clean patching with labelled ports
- Firmware check and secured management access
- Configuration backup and port documentation
- Charged by time, minimum one hour; the amount, travel and material are in the quote.
Payment
- Transfer
- Invoice
- Pay after installation and handover
- SSL-encrypted connection
Installed across Germany
By appointment, on site
Reply the same working day
Email, phone or WhatsApp
Installation by quote
Written quote first
Documented handover
Settings and cabling on paper
Product overview
DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.
Technical specifications
- LEDs
- W/B <a href="" target="_blank" rel="noopener noreferrer">Learn More</a>
- Weight
- 420 g (14.8 oz)
- Buttons
- (1) Factory reset (2) 12V/Dry/24V switch
- Mounting
- Din-rail (Included)
- Dimensions
- 140 x 120 x 45 mm (5.5 x 4.7 x 1.8")
- Power Method
- 12/24V DC
- Power Supply
- DC 12/24V
- UL 294 Level
- Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
Show all 35 specificationsShow fewer
- Digital Input
- (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
- Certifications
- CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- Mount Material
- SGCC steel
- NDAA Compliant
- Yes
- Input Terminals
- (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
- Supported Doors
- 2
- Dry Output Relay
- Lock: rated 30V DC, up to 1A, Aux: rated 30V DC, up to 1A
- UL 294 Statement
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294., The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- Enclosure Material
- Polycarbonate
- Maximum User Count
- 10,000
- Reader Power Output
- 12V DC, up to 0.5A
- Networking Interface
- (2) 10/100 MbE RJ45 ports
- Powered Output Relay
- 12V Lock: 12V DC, up to 1A, 24V Lock: 24V DC, up to 0.5A
- Software Information
- The software version can be checked at <a href="" target="_blank" rel="noopener noreferrer"></a>
- Indoor and Outdoor Use
- Indoor only
- Management Application
- Access
- Max. Power Consumption
- 50W
- CAN/ULC-60839-11-1 Grade
- Grade assignment: I
- PoE Cabling Requirements
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site., The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
- Ambient Operating Humidity
- 5 to 90% noncondensing
- Ambient Operating Temperature
- -10 to 40° C (14 to 104° F)
- Recommend Max. Cable Length · Other locks (1A)
- 24 AWG length: 9 m (30 ft), 22 AWG length: 15 m (49 ft), 20 AWG length: 24 m (79 ft), 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
- Document number, and issue date and/or revision level
- UA-Retrofit-Hub-2, V01
- Recommend Max. Cable Length · UA-Lock-Electric (400mA)
- 24 AWG length: 25 m (82 ft), 22 AWG length: 42 m (138 ft), 20 AWG length: 66 m (217 ft), 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
- Recommend Max. Cable Length · UA-Retrofit-Reader (250mA)
- 18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft)
- Recommend Max. Cable Length · UA-Lock-Magnetic-270kg (800mA)
- 24 AWG length: 12 m (39 ft), 22 AWG length: 20 m (66 ft), 20 AWG length: 30 m (98 ft), 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
- Recommend Max. Cable Length · UA-Lock-Magnetic-540kg (500mA)
- 24 AWG length: 20 m (66 ft), 22 AWG length: 32 m (105 ft), 20 AWG length: 51 m (167 ft), 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
Questions about the Access Retrofit Hub?
Ask before you order: compatibility, PoE budget, cabling or mounting. We reply the same working day.
Access Retrofit Hub installation: installation and configuration
We install and configure the Access Retrofit Hub on site and hand it over documented.
1Rack installation
Mounted, earthed and powered, with cable management so the rack stays serviceable.
2VLAN configuration
Office, guest, VoIP and camera traffic separated, trunks to the firewall and access points.
3Replacing an old switch
Old configuration read out and carried over, changeover planned to keep downtime short.
4Documentation
Port plan, VLAN list and configuration backup handed over.
What is included for this product
- VLANs for office, guests, phones and cameras
- Clean patching with labelled ports
- Firmware check and secured management access
- Configuration backup and port documentation
Price and process
Charged by time, minimum one hour; the amount, travel and material are in the quote.
Tell us briefly what should be installed and where. We reply the same working day and agree an appointment — installation across Germany.
Documents
Frequently asked questions
Can the Access Retrofit Hub be installed outdoors or in unheated areas?
The manufacturer specifies an operating temperature of -10 to 40° C (14 to 104° F). We plan the mounting point and cable entry to match.
What does installing the Access Retrofit Hub cost?
Charged by time, minimum one hour; the amount, travel and material are in the quote. For a firm figure, tell us the site and how many units.
Do you install outside Berlin?
Yes — installation across Germany, by appointment.
How quickly will I hear back?
The same working day. We do not offer a guaranteed response time; the appointment is scheduled by urgency.
Related products