Access Retrofit Hub

1 / 8
Ubiquiti Inc.
Hub
UA-Retrofit-Hub-2

DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.

€260.90incl. installation

Device €235.90 + installation on site €25.00

Included: the device, mounting, connection and commissioning to the usual extent. Travel costs are quoted to you in advance.

Every site is different. If yours needs more — new cable runs, wall openings, work at height or extra devices — you receive a binding quote before we start. Nothing is charged extra without your approval.

Access Retrofit Hub installation service

We install and configure the Access Retrofit Hub on site and hand it over documented. Installation across Germany by quote — we reply the same working day.

  • VLANs for office, guests, phones and cameras
  • Clean patching with labelled ports
  • Firmware check and secured management access
  • Configuration backup and port documentation
  • Charged by time, minimum one hour; the amount, travel and material are in the quote.
Request installation

Payment

  • SEPATransfer
  • Invoice
  • PayPal
  • Pay after installation and handover
  • SSL-encrypted connection
  • Installed across Germany

    By appointment, on site

  • Reply the same working day

    Email, phone or WhatsApp

  • Installation by quote

    Written quote first

  • Documented handover

    Settings and cabling on paper

Product overview

DC-powered hub that supports Wiegand and OSDP readers and provides entry and exit control for up to two doors.

Technical specifications

LEDs
W/B <a href="" target="_blank" rel="noopener noreferrer">Learn More</a>
Weight
420 g (14.8 oz)
Buttons
(1) Factory reset (2) 12V/Dry/24V switch
Mounting
Din-rail (Included)
Dimensions
140 x 120 x 45 mm (5.5 x 4.7 x 1.8")
Power Method
12/24V DC
Power Supply
DC 12/24V
UL 294 Level
Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
Show all 35 specifications
Digital Input
(2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Mount Material
SGCC steel
NDAA Compliant
Yes
Input Terminals
(2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency
Supported Doors
2
Dry Output Relay
Lock: rated 30V DC, up to 1A, Aux: rated 30V DC, up to 1A
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294., The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Enclosure Material
Polycarbonate
Maximum User Count
10,000
Reader Power Output
12V DC, up to 0.5A
Networking Interface
(2) 10/100 MbE RJ45 ports
Powered Output Relay
12V Lock: 12V DC, up to 1A, 24V Lock: 24V DC, up to 0.5A
Software Information
The software version can be checked at <a href="" target="_blank" rel="noopener noreferrer"></a>
Indoor and Outdoor Use
Indoor only
Management Application
Access
Max. Power Consumption
50W
CAN/ULC-60839-11-1 Grade
Grade assignment: I
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site., The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Ambient Operating Humidity
5 to 90% noncondensing
Ambient Operating Temperature
-10 to 40° C (14 to 104° F)
Recommend Max. Cable Length · Other locks (1A)
24 AWG length: 9 m (30 ft), 22 AWG length: 15 m (49 ft), 20 AWG length: 24 m (79 ft), 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
Document number, and issue date and/or revision level
UA-Retrofit-Hub-2, V01
Recommend Max. Cable Length · UA-Lock-Electric (400mA)
24 AWG length: 25 m (82 ft), 22 AWG length: 42 m (138 ft), 20 AWG length: 66 m (217 ft), 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
Recommend Max. Cable Length · UA-Retrofit-Reader (250mA)
18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft)
Recommend Max. Cable Length · UA-Lock-Magnetic-270kg (800mA)
24 AWG length: 12 m (39 ft), 22 AWG length: 20 m (66 ft), 20 AWG length: 30 m (98 ft), 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Recommend Max. Cable Length · UA-Lock-Magnetic-540kg (500mA)
24 AWG length: 20 m (66 ft), 22 AWG length: 32 m (105 ft), 20 AWG length: 51 m (167 ft), 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)

Questions about the Access Retrofit Hub?

Ask before you order: compatibility, PoE budget, cabling or mounting. We reply the same working day.

Installation & service

Access Retrofit Hub installation: installation and configuration

We install and configure the Access Retrofit Hub on site and hand it over documented.

1

Rack installation

Mounted, earthed and powered, with cable management so the rack stays serviceable.

2

VLAN configuration

Office, guest, VoIP and camera traffic separated, trunks to the firewall and access points.

3

Replacing an old switch

Old configuration read out and carried over, changeover planned to keep downtime short.

4

Documentation

Port plan, VLAN list and configuration backup handed over.

What is included for this product

  • VLANs for office, guests, phones and cameras
  • Clean patching with labelled ports
  • Firmware check and secured management access
  • Configuration backup and port documentation

Price and process

Charged by time, minimum one hour; the amount, travel and material are in the quote.

Tell us briefly what should be installed and where. We reply the same working day and agree an appointment — installation across Germany.

Frequently asked questions

Can the Access Retrofit Hub be installed outdoors or in unheated areas?

The manufacturer specifies an operating temperature of -10 to 40° C (14 to 104° F). We plan the mounting point and cable entry to match.

What does installing the Access Retrofit Hub cost?

Charged by time, minimum one hour; the amount, travel and material are in the quote. For a firm figure, tell us the site and how many units.

Do you install outside Berlin?

Yes — installation across Germany, by appointment.

How quickly will I hear back?

The same working day. We do not offer a guaranteed response time; the appointment is scheduled by urgency.

Have the Access Retrofit Hub installed?

We supply, mount and commission it. Ask for a no-obligation quote — we usually reply the same working day.