Server racks and network cabinets · across Germany
Server racks and patch panels for businesses
We build server racks and rework racks that grew without a plan: patch panels terminated, every link certified against the required class, ports labelled and a port list handed over. Across Germany, outside business hours if needed.
In many server racks nobody knows any more which outlet is on which port. That only shows when something fails or has to move – and then every change costs an hour of searching. We build racks from scratch or bring existing ones back to a state you can work in: patch panels neatly terminated, every link tested, every port labelled, and a list that matches the rack. We work in English or German.
- Reply the same working day
- Written quote
- Anywhere in Germany
- Payment after handover
Key figures
- Documentation and administration
- EN 50174-1
- Keeping data and power cables apart
- EN 50174-2
- Port list, also for the cabinet door
- Per port
- Cabinets
- Wall-mounted and floor-standing
- Patch panels
- Cat 6A, fibre splice boxes
- Testing
- Every link, against the class
- Handover
- Port list, also for the door
- Price
- Fixed price after site survey
- Language
- English or German
- Service area
- Anywhere in Germany
- Reply
- The same working day
- Payment
- After handover
Use cases
When businesses call us to the rack
A rack is rarely rebuilt by plan – usually something forces it:
A new rack for an office or a move
Set up the cabinet, fit it out, terminate and test the patch panels before the first outlet is used.
Untangling the cable mess
Nobody knows what is plugged in where: re-patch, shorten and route the cables, label every port and create a list that is correct.
Moving a rack
Dismantle, label, transport, rebuild – evenings or weekends by arrangement.
Installing switches, firewall and UPS
Active equipment installed and commissioned, with power and data routed separately. More: Installing switches, firewall and UPS
Testing and documenting links
Existing patch panels tested and documented before a rebuild, an extension or a takeover. More: Testing and documenting links
For electrical contractors
You provide pathways and power; we take on the data side in the rack – with reports for your acceptance. More: For electrical contractors
Services
What we take on
- Wall-mounted and floor-standing cabinets assembled, including all fittings
- Cat 6A patch panels and fibre splice boxes terminated in the rack
- Grown racks reworked: re-patched, shortened, sorted, routed
- Every link certified against the required class to EN 50173
- Durable labelling of outlets, patch panels and patch cords
- Port documentation: which outlet is on which port of which switch
- Cable management with patch panels for routing and defined cable paths
- Power in the rack in order: PDU, feeds and separate routing
- Switches, firewall and UPS installed and commissioned
- Existing racks rebuilt or relocated, outside business hours by arrangement
What you get at handover
- A port list that matches the labelling in the rack
- Test report for every link
- The port list as a printout for the rack door
- Invoice only after handover
Set-up
A rack you can work in
The order in the rack decides how long the patch cords get and how clear the rack stays. A proven layout from top to bottom:
- 1Top
Patch panels
Incoming links, tested and labelled
- 2Routing
Cable management
Routes the patch cords on short paths
- 3Active equipment
Switches
Right by the patch panel, so cords stay short
- 4Access
Firewall and router
The gateway to the internet
- 5Bottom
UPS and power
Heavy devices at the bottom, feeds routed separately
Data and power cables run separately in the rack: EN 50174-2 sets minimum distances between IT and power cables, depending on cable type and the kind of separation.
Comparison
Wall cabinet, floor-standing rack or open frame?
Which type fits depends on what goes in and where the rack stands:
| Type | Suits | Keep in mind |
|---|---|---|
| Wall cabinet | SuitsSmall offices and floor distributors: patch panels, switches, a small UPS | Keep in mindShallow – usually too shallow for servers; the wall has to carry the weight |
| Floor-standing rack | SuitsServer rooms: servers, UPS, many patch panels | Keep in mindChoose the depth by the deepest device; leave room in front and behind to work |
| Open frame | SuitsLocked technical rooms | Keep in mindNo protection from dust or access – only sensible in locked rooms |
Which type and size you need, we settle during the site survey – with room for the next devices.
Acceptance
How to recognise a documented rack
EN 50174-1 requires documentation and administration for communication cabling – labelling and records that match what is installed. In practice that means:
The port list
- Which outlet in which room
- Which patch-panel port it is on
- Which switch port it is patched to
- The test result of the link
In the rack
- Labels as in the list
- Patch cords of the right length, routed rather than hanging
- Power and data routed separately
- The list as a printout on the rack door
A list that doesn’t match the rack is worse than none: people trust it. That is why our port list comes out of testing and labelling in the same pass.
Cost
What does a server rack build cost?
For a build or a rework we quote a fixed price after the site survey. The quote lists:
| Item | How it is charged |
|---|---|
| Build or rework | Fixed price after site survey |
| Confusing existing rack | A survey first, so you don’t commission blind |
| Materials | Cabinet, patch panels, cable management, cables: itemised |
| Travel | Stated in advance |
| Time-and-materials work, such as fault finding | Time and materials, amount stated in the quote |
| Billing | At least 1 hour, then in full hours |
| Payment | After the work and handover: SEPA bank transfer, invoice or PayPal |
What drives the price
- Number of ports and links
- New build or rework while in use
- Size and type of cabinet
- Installing switches, firewall and UPS
- Travel
Extra work that only shows up on site is agreed with you first – nothing is charged without your consent.
- Transfer
- Invoice
For your purchasing department
Quote
In writing, up front: labour, material and travel are stated before any work starts.
Payment
After the work and handover: SEPA bank transfer, invoice or PayPal. No prepayment.
Contact
We reply the same working day, in English or German.
Supplier details
UltraTech Germany · Leipziger Straße 40, 10117 Berlin, Germany · VAT ID DE463530263 · Legal notice
Quote
For a quote that fits first time
Photos of the open rack from front and back help most.
- Photos of the rack from front and back, doors open
- Number of ports and outlets connected
- What stays and what is added: switches, firewall, UPS
- Whether and when operations may be interrupted
- Wall or floor mounting, room size, ventilation
- Existing documentation, if there is any
- Power: sockets or a PDU in the rack
- Preferred date
Process
How a job runs
- 1
Site survey
We look at the rack and agree what stays, what gets re-terminated and whether we have to work while it is in use.
- 2
Quote
You get a fixed-price quote for the build or the rework. For very confusing existing racks we first offer a survey, so you don’t commission blind.
- 3
Work
Terminate, patch, route and label. While the network is in use we work port by port, so not everything is open at once.
- 4
Testing
Every link is certified. If one fails, we tell you with the measured value instead of quietly waving it through.
- 5
Documentation and handover
You get test reports and a port list that matches the labels in the rack – digitally and as a printout for the rack door. Payment is due after handover.
FAQ
Frequently asked questions
How much does it cost to set up or tidy a server rack?
After the site survey we quote a fixed price. It depends on the number of ports, on whether we build new or rework while in use, and on the equipment that goes in; materials are itemised.
Is tidying an existing rack worth it?
Usually yes. The effort is spent once, while an undocumented rack costs time at every change and every fault. If the rack is too small or the cabling is old throughout, we tell you – then a rebuild is more honest than expensive cosmetics.
What size of rack do we need?
Height follows from the devices in rack units plus room for patch panels, cable management and later additions. Depth follows the deepest device: patch panels and switches often fit a shallow wall cabinet, servers usually need a deep floor-standing rack. We settle this during the site survey.
Do we have to stop operations?
Usually not. We work port by port and agree which areas may be briefly interrupted when. For larger rebuilds or rack moves we work evenings or weekends if you want.
What is in the port documentation?
Which outlet in which room is on which patch-panel port, which switch port it is patched to, and the test result of the link. The labels in the rack match the list, so both can be used together.
Why test if the connection works?
“Works” does not mean the link reaches its class. A link just below the limits often runs unnoticed at gigabit and fails as soon as more load or a higher speed is added. Certification shows the margin; a continuity test does not.
Do you install the active equipment too?
We install and commission switches, firewall and UPS. Setting up servers and applications is not our area – there we work with your IT service provider.
Can we work with you in English?
Yes. You can reach us and work with us in English or German.
How do we pay?
After the work and handover, by SEPA bank transfer, invoice or PayPal.
Sources
Standards and sources
Where a standard or a law gives a number, this page states it with its source. Where sources disagree, we give no number – your specification decides.
Next
Related services
Enquiry about Server racks and patch panels
- Free initial consultation
- Reply the same working day
- Work by appointment
- across Germany
For a quote that fits first time
- Photos of the rack from front and back, doors open
- Number of ports and outlets connected
- What stays and what is added: switches, firewall, UPS
- Whether and when operations may be interrupted
- Wall or floor mounting, room size, ventilation
- Existing documentation, if there is any
- Power: sockets or a PDU in the rack
- Preferred date
- Transfer
- Invoice