UUltraTechGermany

Server racks and network cabinets · across Germany

Server racks and patch panels for businesses

We build server racks and rework racks that grew without a plan: patch panels terminated, every link certified against the required class, ports labelled and a port list handed over. Across Germany, outside business hours if needed.

In many server racks nobody knows any more which outlet is on which port. That only shows when something fails or has to move – and then every change costs an hour of searching. We build racks from scratch or bring existing ones back to a state you can work in: patch panels neatly terminated, every link tested, every port labelled, and a list that matches the rack. We work in English or German.

  • Reply the same working day
  • Written quote
  • Anywhere in Germany
  • Payment after handover

Key figures

Documentation and administration
EN 50174-1
Keeping data and power cables apart
EN 50174-2
Port list, also for the cabinet door
Per port
Standards and sources
Cabinets
Wall-mounted and floor-standing
Patch panels
Cat 6A, fibre splice boxes
Testing
Every link, against the class
Handover
Port list, also for the door
Price
Fixed price after site survey
Language
English or German
Service area
Anywhere in Germany
Reply
The same working day
Payment
After handover

Use cases

When businesses call us to the rack

A rack is rarely rebuilt by plan – usually something forces it:

Services

What we take on

  • Wall-mounted and floor-standing cabinets assembled, including all fittings
  • Cat 6A patch panels and fibre splice boxes terminated in the rack
  • Grown racks reworked: re-patched, shortened, sorted, routed
  • Every link certified against the required class to EN 50173
  • Durable labelling of outlets, patch panels and patch cords
  • Port documentation: which outlet is on which port of which switch
  • Cable management with patch panels for routing and defined cable paths
  • Power in the rack in order: PDU, feeds and separate routing
  • Switches, firewall and UPS installed and commissioned
  • Existing racks rebuilt or relocated, outside business hours by arrangement

What you get at handover

  • A port list that matches the labelling in the rack
  • Test report for every link
  • The port list as a printout for the rack door
  • Invoice only after handover

Set-up

A rack you can work in

The order in the rack decides how long the patch cords get and how clear the rack stays. A proven layout from top to bottom:

  1. 1
    Top

    Patch panels

    Incoming links, tested and labelled

  2. 2
    Routing

    Cable management

    Routes the patch cords on short paths

  3. 3
    Active equipment

    Switches

    Right by the patch panel, so cords stay short

  4. 4
    Access

    Firewall and router

    The gateway to the internet

  5. 5
    Bottom

    UPS and power

    Heavy devices at the bottom, feeds routed separately

Data and power cables run separately in the rack: EN 50174-2 sets minimum distances between IT and power cables, depending on cable type and the kind of separation.

Comparison

Wall cabinet, floor-standing rack or open frame?

Which type fits depends on what goes in and where the rack stands:

Wall cabinetSuitsSmall offices and floor distributors: patch panels, switches, a small UPSKeep in mindShallow – usually too shallow for servers; the wall has to carry the weight
Floor-standing rackSuitsServer rooms: servers, UPS, many patch panelsKeep in mindChoose the depth by the deepest device; leave room in front and behind to work
Open frameSuitsLocked technical roomsKeep in mindNo protection from dust or access – only sensible in locked rooms

Which type and size you need, we settle during the site survey – with room for the next devices.

Acceptance

How to recognise a documented rack

EN 50174-1 requires documentation and administration for communication cabling – labelling and records that match what is installed. In practice that means:

The port list

  • Which outlet in which room
  • Which patch-panel port it is on
  • Which switch port it is patched to
  • The test result of the link

In the rack

  • Labels as in the list
  • Patch cords of the right length, routed rather than hanging
  • Power and data routed separately
  • The list as a printout on the rack door

A list that doesn’t match the rack is worse than none: people trust it. That is why our port list comes out of testing and labelling in the same pass.

Cost

What does a server rack build cost?

For a build or a rework we quote a fixed price after the site survey. The quote lists:

ItemHow it is charged
Build or reworkFixed price after site survey
Confusing existing rackA survey first, so you don’t commission blind
MaterialsCabinet, patch panels, cable management, cables: itemised
TravelStated in advance
Time-and-materials work, such as fault findingTime and materials, amount stated in the quote
BillingAt least 1 hour, then in full hours
PaymentAfter the work and handover: SEPA bank transfer, invoice or PayPal

What drives the price

  • Number of ports and links
  • New build or rework while in use
  • Size and type of cabinet
  • Installing switches, firewall and UPS
  • Travel

Extra work that only shows up on site is agreed with you first – nothing is charged without your consent.

  • SEPATransfer
  • Invoice
  • PayPal

For your purchasing department

  • Quote

    In writing, up front: labour, material and travel are stated before any work starts.

  • Payment

    After the work and handover: SEPA bank transfer, invoice or PayPal. No prepayment.

  • Contact

    We reply the same working day, in English or German.

  • Supplier details

    UltraTech Germany · Leipziger Straße 40, 10117 Berlin, Germany · VAT ID DE463530263 · Legal notice

Quote

For a quote that fits first time

Photos of the open rack from front and back help most.

  • Photos of the rack from front and back, doors open
  • Number of ports and outlets connected
  • What stays and what is added: switches, firewall, UPS
  • Whether and when operations may be interrupted
  • Wall or floor mounting, room size, ventilation
  • Existing documentation, if there is any
  • Power: sockets or a PDU in the rack
  • Preferred date

Process

How a job runs

  1. 1

    Site survey

    We look at the rack and agree what stays, what gets re-terminated and whether we have to work while it is in use.

  2. 2

    Quote

    You get a fixed-price quote for the build or the rework. For very confusing existing racks we first offer a survey, so you don’t commission blind.

  3. 3

    Work

    Terminate, patch, route and label. While the network is in use we work port by port, so not everything is open at once.

  4. 4

    Testing

    Every link is certified. If one fails, we tell you with the measured value instead of quietly waving it through.

  5. 5

    Documentation and handover

    You get test reports and a port list that matches the labels in the rack – digitally and as a printout for the rack door. Payment is due after handover.

FAQ

Frequently asked questions

How much does it cost to set up or tidy a server rack?

After the site survey we quote a fixed price. It depends on the number of ports, on whether we build new or rework while in use, and on the equipment that goes in; materials are itemised.

Is tidying an existing rack worth it?

Usually yes. The effort is spent once, while an undocumented rack costs time at every change and every fault. If the rack is too small or the cabling is old throughout, we tell you – then a rebuild is more honest than expensive cosmetics.

What size of rack do we need?

Height follows from the devices in rack units plus room for patch panels, cable management and later additions. Depth follows the deepest device: patch panels and switches often fit a shallow wall cabinet, servers usually need a deep floor-standing rack. We settle this during the site survey.

Do we have to stop operations?

Usually not. We work port by port and agree which areas may be briefly interrupted when. For larger rebuilds or rack moves we work evenings or weekends if you want.

What is in the port documentation?

Which outlet in which room is on which patch-panel port, which switch port it is patched to, and the test result of the link. The labels in the rack match the list, so both can be used together.

Why test if the connection works?

“Works” does not mean the link reaches its class. A link just below the limits often runs unnoticed at gigabit and fails as soon as more load or a higher speed is added. Certification shows the margin; a continuity test does not.

Do you install the active equipment too?

We install and commission switches, firewall and UPS. Setting up servers and applications is not our area – there we work with your IT service provider.

Can we work with you in English?

Yes. You can reach us and work with us in English or German.

How do we pay?

After the work and handover, by SEPA bank transfer, invoice or PayPal.

Sources

Standards and sources

Where a standard or a law gives a number, this page states it with its source. Where sources disagree, we give no number – your specification decides.

Show sources
  1. [1]EN 50174-1 – specification and quality assurance
  2. [2]Voltimum: requirements of EN 50174-2 (German)

Enquiry about Server racks and patch panels

  • Free initial consultation
  • Reply the same working day
  • Work by appointment
  • across Germany
Request a quote+49 30 50930365

For a quote that fits first time

  • Photos of the rack from front and back, doors open
  • Number of ports and outlets connected
  • What stays and what is added: switches, firewall, UPS
  • Whether and when operations may be interrupted
  • Wall or floor mounting, room size, ventilation
  • Existing documentation, if there is any
  • Power: sockets or a PDU in the rack
  • Preferred date
  • SEPATransfer