UUltraTechGermany

Fibre testing · across Germany

Fibre testing for businesses

We test fibre links for businesses across Germany to ISO/IEC 14763-3, with our own power meter and light source and, where needed, an OTDR, and hand over a report for every fibre. The first consultation is free. Acceptance and survey testing is offered at a fixed price per link, fault finding is charged by time. After a cable break, the OTDR shows where along the fibre the fault is.

Technically reviewed by M. Ahmed – 13 years of professional experience

At a glance

Method
Loss measurement, OTDR
Standard
ISO/IEC 14763-3
Fibre
OS2, OM3, OM4, OM5
Report
Per fibre, with pass/fail
Consultation
First consultation free
Price
Fixed price per link
Language
English or German
Service area
Anywhere in Germany

Our own equipment

  • OTDRFault location, every splice on its own

  • Power meter and light sourceLoss of the whole link

  • Inspection microscopeChecking connector end faces

  • Fusion splicerRepair splice after fault location

In plain words

What do the technical terms mean?

You don’t need to know any of these words to send an enquiry. You will meet them in the quote and the report, though:

  • OTDR

    An instrument that sends pulses of light into the fibre and reads from the returning light where a splice, a connector or a fault is. It shows the length of the fibre, not the path of the cable through the ground.

  • Loss (attenuation)

    The share of light that gets lost on its way through the fibre, given in decibels (dB). Every splice, every connector and every bend that is too tight costs a little.

  • Loss budget

    The most loss a link may have so that enough light still arrives at the end. The faster the application, the smaller the budget. It is set out in the standard or in your specification.

  • Launch fibre

    A length of fibre plugged in between the instrument and the link. Without it the first connector of the link could not be judged, because the instrument is briefly “blind” right after the pulse.

  • Event and reflection

    An event is any point on the trace where something changes: a splice, a connector, a bend or a break. A reflection is light thrown back at a connector or a break.

  • Power-meter test (LSPM)

    A light source feeds light in at one end of the link and a power meter at the other end measures how much arrives. The difference is the total loss. The standard recommends this method for acceptance.

  • Bidirectional testing

    Testing from both ends of the link. A splice looks better from one direction and worse from the other; only the average is right.

  • Single-mode and multimode

    Single-mode fibre (OS2) has a very thin core and carries light over long distances. Multimode fibre (OM3 to OM5) has a thicker core and is mostly found inside buildings. The type is usually printed on the cable sheath.

Use cases

When should you have your fibre tested?

Testing happens before anyone signs for a link, pays for it or relies on it:

The installer says the link is finished, yet the network does not run as fast as you ordered. Or you are taking over a building and nobody can say what the fibres in the basement are still worth. Or a connection drops and no one knows where. In all three cases a measurement helps: it shows whether a link meets the required values and, if not, where the problem is. We test to the standard, judge the results against the limits in your specification and hand over a report that holds up at acceptance. You do not need to know the technical terms: we explain them below. We work in English or German.

  • Acceptance after a new build

    We test new links against your specification before you accept and pay. The report is your evidence towards the installer.

  • Taking over a building or space

    Before buying, renting or taking over a network: what are the existing links worth? We document the condition – even if it fails.

  • Upgrading to 10, 25 or 100 Gbit/s

    The higher the data rate, the smaller the loss budget. Testing shows beforehand whether an existing link is good enough for the new transceivers.

  • Cable breaks and faults

    The OTDR shows where along the fibre the fault is. Then we set the repair splice. Appointments by urgency. More: Cable breaks and faults

  • After splicing

    The splicer only estimates the loss. Only a measurement of the finished link proves it meets the values. More: After splicing

  • For installers and IT service providers

    You install, we test – with our own test equipment and reports for your acceptance. More: For installers and IT service providers

A team of independent specialists, one contact from enquiry to handover.

1.9 dB
100 Gbit/s over OM4/OM5 at 100 m (EN 50173-1)
IEC 61300-3-35
Endface inspection before testing
Per fibre
Report with a verdict against the budget

Services

What do we test and hand over?

  • Loss measurement with light source and power meter to ISO/IEC 14763-3 (IEC 61280-4-1 / -4-2)
  • OTDR testing to judge individual splices and connectors, in both directions where the standard requires it
  • Endface inspection before measuring (IEC 61300-3-35)
  • Fault location after a cable break or fault
  • Testing of existing links before commissioning, takeover or an upgrade
  • Acceptance testing for building owners, general contractors and IT service providers
  • Digital test report for every fibre, with pass/fail

What you get at handover

  • Test report for every fibre with pass/fail, digital
  • With OTDR testing, the trace of every fibre
  • On request, a summary of anything conspicuous
  • Invoice only after handover

Set-up

How acceptance testing to ISO/IEC 14763-3 runs

The standard sets the steps. Skip one, and in the end you measure the test set-up instead of the link:

  1. 1
    Required

    Inspect connectors

    Check endfaces to IEC 61300-3-35, clean or replace

  2. 2
    Required

    Set the reference

    Fit reference cords and check their quality

  3. 3
    Required

    Measure loss

    Light source and power meter, per fibre and wavelength

  4. 4
    Required

    Evaluate

    Against the loss budget from the standard or your specification

  5. 5
    If needed

    OTDR

    When the budget is exceeded or individual events need judging

Under EN 50173-1, the loss of a link may not exceed the sum of the values of its components. That is why the standard recommends the loss measurement for acceptance; OTDR adds to it where individual events matter.

Comparison

Loss measurement, OTDR or visual fault locator?

Three methods, three different answers. Your specification decides:

Loss measurement with light source and power meterWe offer thisWhat it showsTotal loss of the link per fibre and wavelengthWhat it is forAcceptance against the loss budget – the method the standard recommends
OTDRWe offer thisWhat it showsThe trace along the link: every connector, every splice, distance to faultsWhat it is forJudging individual splices and connectors, locating faults, documenting what exists
Visual fault locator (red light)What it showsWhether light gets through, and where a fibre breaks within sightWhat it is forIdentifying fibres and quick checks – not a measurement

We test with light source and power meter and with OTDR – separately or together, depending on what your acceptance requires.

Acceptance

What belongs in the report – and what to fix beforehand

A report is only as good as the criteria it was tested against:

In the test report

  • Method and standard
  • The limits tested against
  • Result per fibre and wavelength, with pass/fail
  • With OTDR, the trace with every event

Fix beforehand

  • Limit: standard and edition, or your own value in the specification
  • Method: loss measurement, OTDR or both
  • Wavelengths: 850 and 1300 nm (multimode), 1310 and 1550 nm (single-mode)
  • For 25 or 100 Gbit/s, the budget of the planned application – EN 50173-1 gives 1.9 dB for 100 Gbit/s over OM4/OM5 at 100 m

If the two ends of a link have different connectors, the current 3rd edition of ISO/IEC 14763-3 is not enough: it dropped the three-cord reference method. Until further notice, the German standards body DKE recommends the 2nd edition (DIN ISO/IEC 14763-3:2019-05) for this case. We agree this with you before testing.

Cost

What does a fibre or OTDR test cost?

The first consultation is free; for acceptance and survey testing we quote a fixed price up front. The quote lists:

ItemHow it is charged
Acceptance and survey testingFixed price per tested link
Method and limitsSet out in writing
TravelStated in advance
Fault finding and fault locationTime and materials, amount stated in the quote
BillingAt least 1 hour, then in full hours
PaymentAfter the work and handover: SEPA bank transfer, invoice or PayPal

What drives the price

  • Number of links and fibres
  • Method: loss measurement, OTDR or both
  • One direction or both
  • Access to both ends of the link
  • Travel

Extra work that only shows up on site is agreed with you first – nothing is charged without your consent.

  • SEPATransfer
  • Invoice
  • PayPal

For your purchasing department

  • Quote

    In writing, up front: labour, material and travel are stated before any work starts.

  • Payment

    After the work and handover: SEPA bank transfer, invoice or PayPal. No prepayment.

  • Contact

    We reply the same working day, in English or German.

  • Supplier details

    UltraTech Germany · Leipziger Straße 40, 10117 Berlin, Germany · VAT ID DE463530263 · Legal notice

Quote

For a quote that fits first time

With these details we can give a fixed price. What you don’t know, we clarify – a photo of both ends often does it.

Show all details
  • Fibre type: single-mode (OS2) or multimode (OM3, OM4, OM5)
  • Number of links and fibres, approximate lengths
  • Connector and polish at both ends (for example LC, SC, E2000; UPC or APC)
  • Purpose: acceptance, survey, upgrade or fault finding
  • Limits or standard from your specification, if any
  • Access to both ends: rooms, keys, a contact
  • For a fault: since when, what changed beforehand, the route plan
  • Preferred date

Process

How does a test run?

  1. 1

    Scope

    Tell us the number of links, the fibre type, the connectors at both ends and the purpose – acceptance, survey or fault finding. We reply the same working day.

  2. 2

    Quote and test criteria

    You get the fixed price per link and, in writing, the standard, limits and method we will test against – before anyone travels.

  3. 3

    Testing on site

    Inspect and clean the connectors, set the reference, measure – in both directions where the standard or your specification requires it. Every fibre is documented individually.

  4. 4

    Evaluation

    We judge the results against the limits and point out conspicuous splices or connectors.

  5. 5

    Report and handover

    You get the test report digitally. Payment is due after handover.

FAQ

Frequently asked questions

How does an OTDR test work?

An OTDR sends short pulses of light into the fibre and measures how much light comes back from each point. From the timing we see where a splice, a connector or a fault is, and from the strength how much light is lost there. The result is a trace for every fibre. A short launch fibre sits between the instrument and your link, so that even the first connector can be judged. You do not have to prepare anything: tell us which link it is and we take care of the rest.

How do you read an OTDR trace?

The trace shows the link from left to right. A straight, gently falling line is the fibre itself; its slope is the loss. A small step down is usually a splice, a step with a spike in front of it a connector, a large drop at the end the fibre end or a break. We judge each of these events against the limits in your specification, in both directions where that is required. You receive the trace and the verdict in the report.

How can I test a fibre cable?

There are three ways, and each answers something different. A visual fault locator (red light) shows whether any light gets through. A light source and power meter measure how much light is lost over the whole link; that is the method for acceptance. An OTDR shows every splice and connector on its own. A result you can rely on needs instruments, clean connectors and experience. Tell us the link and the purpose, and we will tell you which method is enough.

How much loss is allowed in a fibre link?

It depends on the link and the application, so we do not quote one blanket figure. Every link has a loss budget: the most loss it may have. Under EN 50173-1, the loss of a link may not exceed the sum of the values of its components. The faster the application, the smaller the budget; for 100 Gbit/s over OM4/OM5 at 100 m the standard gives 1.9 dB. The limit that applies to you is in your specification or the equipment data sheet. Send us both and we will check them.

What limits apply to an OTDR test?

There is not one figure for everyone. The limits for individual splices and connectors are set by the standard, its edition and your specification, and sources differ from each other. That is why we agree them with you in writing before testing instead of guessing. For acceptance of the whole link the standard recommends the loss measurement; the OTDR additionally judges individual events. Do you already have requirements? Send them over and we will test against them.

Does an OTDR test work on multimode fibre?

Yes. The OTDR needs a multimode module that matches your fibre, and it measures at 850 and 1300 nm. The trace is less sharp on multimode than on single-mode, because the light travels along several paths; individual events can still be judged. For acceptance of a multimode link the standard recommends measuring with light source and power meter; the OTDR is added depending on your requirements. Not sure which fibre you have? A photo of the cable sheath is often enough.

How much does a fibre or OTDR test cost?

The first consultation is free. Acceptance and survey testing is offered at a fixed price per tested link, which you read in the quote beforehand; fault finding is charged by time, with the amount stated in the quote. The price depends on the number of links and fibres, the method, one or both directions, access to both ends and travel. Payment is after handover, by SEPA bank transfer, invoice or PayPal. Write to us briefly with what you have and we will give you the price.

Loss measurement or OTDR: what do we need for acceptance?

For acceptance to ISO/IEC 14763-3 you need the loss measurement with light source and power meter: it shows whether the link stays within its loss budget. The OTDR is added when the budget is exceeded, when individual splices and connectors need judging, or when your specification asks for it. Tell us what the contract says and we will clarify the rest.

Which standard do you test to?

We test to ISO/IEC 14763-3, which covers testing installed fibre cabling to EN 50173. The loss measurement itself follows IEC 61280-4-1 for multimode and IEC 61280-4-2 for single-mode. If your specification refers to EN 50346 or a particular edition, we test to that. If the two ends of a link have different connectors, we agree the method with you before testing.

How precisely does an OTDR locate a cable break?

The OTDR measures the length of the fibre up to the fault, not the path of the cable in the ground. The fibre is longer than the route, because it lies in the cable with excess length and there are slack loops. With the route plan and the metre markings on the cable sheath, the spot can be narrowed down before anyone opens or digs. A broken cable can be repaired. Send us the plan and a photo of the cable and we will tell you how we would go about it.

Why test in both directions?

Because an OTDR shows a splice between two fibres with a slightly different light spot too good from one side and too bad from the other. Only the average of both is right. Where the standard or your specification requires it, we therefore test from both ends. For that we need access to both sides of the link; please tell us beforehand where the ends are.

Will our link carry 25 or 100 Gbit/s?

The measurement shows it. The higher the data rate, the smaller the permitted loss budget: EN 50173-1 gives an insertion loss of 1.9 dB for 100 Gbit/s over four OM4/OM5 fibre pairs at 100 m. We test your link and compare it with the budget of the planned application. That way you know before buying the transceivers whether it fits.

Do we get a report, even for links you did not install?

Yes. After every test you receive a digital report per fibre with method, limits and result, which can serve as evidence for acceptance. That includes existing links: we document the condition we find, even if it fails the values. You then have a basis for acceptance, a purchase or a complaint.

How soon can you come?

We reply to every enquiry the same working day. Appointments are booked by urgency; a fault that stops operations comes first. We do not offer a guaranteed response time. Work outside business hours is possible by arrangement. Tell us what has failed and we will plan the next step.

Sources

Standards and sources

Where a standard or a law gives a number, this page states it with its source. Where sources disagree, we give no number – your specification decides.

Show sources
  1. [1]DKE: interpretation of ISO/IEC 14763-3 – testing fibre cabling (2024, German)
  2. [2]EN 50173-1 – generic cabling systems
  3. [3]IEC 61300-3-35 – visual inspection of fibre optic connector endfaces
  4. [4]Borzycki, Gajewski: OTDR distance and cable length, JTiT 4/2021

Enquiry about Fibre testing and OTDR for businesses

  • Free initial consultation
  • Reply the same working day
  • Work by appointment
  • across Germany
Request a quote+49 30 50930365

For a quote that fits first time

  • Fibre type: single-mode (OS2) or multimode (OM3, OM4, OM5)
  • Number of links and fibres, approximate lengths
  • Connector and polish at both ends (for example LC, SC, E2000; UPC or APC)
  • Purpose: acceptance, survey, upgrade or fault finding
  • Limits or standard from your specification, if any
  • Access to both ends: rooms, keys, a contact
  • For a fault: since when, what changed beforehand, the route plan
  • Preferred date
  • SEPATransfer
  • Invoice
  • PayPal