# Server racks and patch panels for businesses

> We build server racks and rework racks that grew without a plan: patch panels terminated, every link certified against the required class, ports labelled and a port list handed over. Across Germany, outside business hours if needed.

URL: https://utechit.de/business/server-rack
Alternate language version: https://utechit.de/de/business/serverschrank-patchfeld
Language: en
Provider: UltraTech Germany, Leipziger Straße 40, 10117 Berlin
Service area: Deutschland

In many server racks nobody knows any more which outlet is on which port. That only shows when something fails or has to move – and then every change costs an hour of searching. We build racks from scratch or bring existing ones back to a state you can work in: patch panels neatly terminated, every link tested, every port labelled, and a list that matches the rack. We work in English or German.

## Key figures

- **EN 50174-1** — Documentation and administration
- **EN 50174-2** — Keeping data and power cables apart
- **Per port** — Port list, also for the cabinet door

## When businesses call us to the rack

- **A new rack for an office or a move** — Set up the cabinet, fit it out, terminate and test the patch panels before the first outlet is used.
- **Untangling the cable mess** — Nobody knows what is plugged in where: re-patch, shorten and route the cables, label every port and create a list that is correct.
- **Moving a rack** — Dismantle, label, transport, rebuild – evenings or weekends by arrangement.
- **Installing switches, firewall and UPS** — Active equipment installed and commissioned, with power and data routed separately.
- **Testing and documenting links** — Existing patch panels tested and documented before a rebuild, an extension or a takeover.
- **For electrical contractors** — You provide pathways and power; we take on the data side in the rack – with reports for your acceptance.

## What we deliver

- Wall-mounted and floor-standing cabinets assembled, including all fittings
- Cat 6A patch panels and fibre splice boxes terminated in the rack
- Grown racks reworked: re-patched, shortened, sorted, routed
- Every link certified against the required class to EN 50173
- Durable labelling of outlets, patch panels and patch cords
- Port documentation: which outlet is on which port of which switch
- Cable management with patch panels for routing and defined cable paths
- Power in the rack in order: PDU, feeds and separate routing
- Switches, firewall and UPS installed and commissioned
- Existing racks rebuilt or relocated, outside business hours by arrangement

## A rack you can work in

The order in the rack decides how long the patch cords get and how clear the rack stays. A proven layout from top to bottom:

1. **Patch panels** — Incoming links, tested and labelled
2. **Cable management** — Routes the patch cords on short paths
3. **Switches** — Right by the patch panel, so cords stay short
4. **Firewall and router** — The gateway to the internet
5. **UPS and power** — Heavy devices at the bottom, feeds routed separately

Data and power cables run separately in the rack: EN 50174-2 sets minimum distances between IT and power cables, depending on cable type and the kind of separation.

## Wall cabinet, floor-standing rack or open frame?

Which type fits depends on what goes in and where the rack stands:

| Type | Suits | Keep in mind |
| --- | --- | --- |
| Wall cabinet | Small offices and floor distributors: patch panels, switches, a small UPS | Shallow – usually too shallow for servers; the wall has to carry the weight |
| Floor-standing rack | Server rooms: servers, UPS, many patch panels | Choose the depth by the deepest device; leave room in front and behind to work |
| Open frame | Locked technical rooms | No protection from dust or access – only sensible in locked rooms |

Which type and size you need, we settle during the site survey – with room for the next devices.

## How to recognise a documented rack

EN 50174-1 requires documentation and administration for communication cabling – labelling and records that match what is installed. In practice that means:

**The port list**

- Which outlet in which room
- Which patch-panel port it is on
- Which switch port it is patched to
- The test result of the link

**In the rack**

- Labels as in the list
- Patch cords of the right length, routed rather than hanging
- Power and data routed separately
- The list as a printout on the rack door

A list that doesn’t match the rack is worse than none: people trust it. That is why our port list comes out of testing and labelling in the same pass.

## What you get at handover

- A port list that matches the labelling in the rack
- Test report for every link
- The port list as a printout for the rack door
- Invoice only after handover

## What does a server rack build cost?

For a build or a rework we quote a fixed price after the site survey. The quote lists:

- **Build or rework:** Fixed price after site survey
- **Confusing existing rack:** A survey first, so you don’t commission blind
- **Materials:** Cabinet, patch panels, cable management, cables: itemised
- **Travel:** Stated in advance

What drives the price:

- Number of ports and links
- New build or rework while in use
- Size and type of cabinet
- Installing switches, firewall and UPS
- Travel

 Payment after installation and handover: SEPA bank transfer, invoice or PayPal.

## For a quote that fits first time

Photos of the open rack from front and back help most.

- Photos of the rack from front and back, doors open
- Number of ports and outlets connected
- What stays and what is added: switches, firewall, UPS
- Whether and when operations may be interrupted
- Wall or floor mounting, room size, ventilation
- Existing documentation, if there is any
- Power: sockets or a PDU in the rack
- Preferred date

## How a job runs

1. **Site survey** — We look at the rack and agree what stays, what gets re-terminated and whether we have to work while it is in use.
2. **Quote** — You get a fixed-price quote for the build or the rework. For very confusing existing racks we first offer a survey, so you don’t commission blind.
3. **Work** — Terminate, patch, route and label. While the network is in use we work port by port, so not everything is open at once.
4. **Testing** — Every link is certified. If one fails, we tell you with the measured value instead of quietly waving it through.
5. **Documentation and handover** — You get test reports and a port list that matches the labels in the rack – digitally and as a printout for the rack door. Payment is due after handover.

## Frequently asked questions

### How much does it cost to set up or tidy a server rack?

After the site survey we quote a fixed price. It depends on the number of ports, on whether we build new or rework while in use, and on the equipment that goes in; materials are itemised.

### Is tidying an existing rack worth it?

Usually yes. The effort is spent once, while an undocumented rack costs time at every change and every fault. If the rack is too small or the cabling is old throughout, we tell you – then a rebuild is more honest than expensive cosmetics.

### What size of rack do we need?

Height follows from the devices in rack units plus room for patch panels, cable management and later additions. Depth follows the deepest device: patch panels and switches often fit a shallow wall cabinet, servers usually need a deep floor-standing rack. We settle this during the site survey.

### Do we have to stop operations?

Usually not. We work port by port and agree which areas may be briefly interrupted when. For larger rebuilds or rack moves we work evenings or weekends if you want.

### What is in the port documentation?

Which outlet in which room is on which patch-panel port, which switch port it is patched to, and the test result of the link. The labels in the rack match the list, so both can be used together.

### Why test if the connection works?

“Works” does not mean the link reaches its class. A link just below the limits often runs unnoticed at gigabit and fails as soon as more load or a higher speed is added. Certification shows the margin; a continuity test does not.

### Do you install the active equipment too?

We install and commission switches, firewall and UPS. Setting up servers and applications is not our area – there we work with your IT service provider.

### Can we work with you in English?

Yes. You can reach us and work with us in English or German.

### How do we pay?

After the work and handover, by SEPA bank transfer, invoice or PayPal.

## Standards and sources

- [EN 50174-1 – specification and quality assurance](https://www.dinmedia.de/de/norm/din-en-50174-1/327617657)
- [Voltimum: requirements of EN 50174-2 (German)](https://content.voltimum.com/de/127381/de_2021_01_anforderung-din_en_50174-2_.pdf)

## Contact