# Network troubleshooting and cable faults for businesses

> We narrow down network faults on copper and fibre links by measurement and locate fibre breaks by OTDR. Report a fault and you hear back the same working day; we book the appointment by urgency.

URL: https://utechit.de/business/network-troubleshooting
Alternate language version: https://utechit.de/de/business/netzwerkstoerung
Language: en
Provider: UltraTech Germany, Leipziger Straße 40, 10117 Berlin
Service area: Deutschland

When something fails, the first reflex is to swap: the switch, then the patch cord, then the router – and in the end it is a link that was never tested. We work the other way round and measure first. On fibre, an OTDR shows where along the fibre the break is; on copper, a certifier shows whether the link reaches its class at all. That saves replacing equipment that was never faulty. We work in English or German.

## Key figures

- **Same working day** — Reply to your fault report
- **Bottom-up** — Narrowing down from the cable upwards
- **1 hour** — Minimum, then full hours

## Typical faults we are called to

- **An area without network** — A floor, a room, a part of the building is down: link, uplink or switch – the measurement shows which.
- **Intermittent drop-outs** — Sometimes it works, sometimes not: often a link right at the limit that a continuity test reports as fine.
- **Fibre between buildings dead** — After construction work or for no visible reason: the OTDR shows where along the fibre the break is; then comes the repair splice.
- **Network slow at certain times** — An overloaded uplink, a backup at the wrong time or WLAN channels: we narrow it down instead of recommending new hardware.
- **After a refit or a move** — Nothing has worked since the refit, and nobody knows what was re-patched: check the patching, test the links, document.
- **For IT service providers and electricians** — When your test or splicing equipment isn’t available: we test and repair; the report goes to you.

## What we deliver

- Narrowing down the fault: link, active equipment or configuration
- Fault location on fibre by OTDR – distance to the break
- Copper links certified against the required class
- Repair splice and restoration of the link, with a report
- A temporary workaround if the final repair takes longer
- Checking patch panel, patching and port assignment where documentation is unclear
- Test report of the restored link for your records
- A short report with cause and recommendation, so the same fault does not return

## Narrowing down from the bottom up

We search in the order in which faults are cheapest to rule out – the link first, then the equipment:

1. **Link** — Copper with a certifier, fibre with an OTDR
2. **Ports and patch cords** — Patching, connectors, port status on the switch
3. **Switch and PoE** — Uplinks, error counters, PoE budget
4. **Configuration** — VLANs, address assignment, loops in the network
5. **Internet connection** — The provider’s handover point

If the cause is the provider’s connection, we tell you so with a measured value – you then report the fault there, with hard facts instead of guesses.

## Symptom, possible cause, how to find it

The symptom often already tells you where to look:

| Symptom | Possible cause | How to find it |
| --- | --- | --- |
| A whole area without network | Cable break, failed switch or uplink, power supply | Test the link, check switch and uplink |
| Intermittent drop-outs | Link at the limit, connector, too tight a bend, a loop in the network | Certification, error counters on the switch |
| Slow at certain times | Overloaded uplink, backups, WLAN channels | Measure utilisation, survey the WLAN |
| Single devices without connection | Address conflict, wrong VLAN, disabled port | Check configuration and port status |
| Access points or cameras restart | Switch PoE budget exhausted, poor link | Check PoE budget, test the link |
| Only the internet fails | Connection or router at the provider | Check up to the handover point, report to the provider |

The table does not replace a measurement – but it helps you word the report so we bring the right test equipment.

## What you know after the visit

A fault is only dealt with once it is clear why it happened:

**What you get**

- Test report of the restored link
- The cause, as far as it can be measured
- A recommendation so the same fault does not return

**What we name clearly**

- When the cause is not in the cabling
- What lies outside our area – such as servers, applications or the provider’s connection
- When a link is marginal and may fail again soon

If the final repair is more involved, we first set up a workaround so operations continue – and then plan the repair with you.

## What you get at handover

- Test report of the restored link
- Short report with cause and recommendation
- Invoice only after the visit

## What does troubleshooting cost?

Troubleshooting is charged by time – nobody knows beforehand how long narrowing down takes. Up front we state:

- **Travel:** Stated in advance
- **Repair materials:** Pigtails, cables, connectors: itemised
- **Extra effort:** We get in touch before the effort exceeds the estimate

What drives the price:

- How well the installation is documented
- Number of affected links
- Whether a repair splice or a new cable is needed
- Access to both ends of the link
- Travel

 Payment after installation and handover: SEPA bank transfer, invoice or PayPal.

## So we bring the right test equipment

The more precise the report, the more likely the first visit is also the last.

- What failed, and since when
- Whether copper, fibre or both are affected
- What has already been swapped or checked
- Whether there was building work, a refit or re-patching beforehand
- Photos of the rack, patch panel and the switch LEDs
- Existing documentation or route plan
- Access to both ends of the affected links
- A contact who can be reached on site

## How a job runs

1. **Report** — Tell us briefly what failed and since when. You hear back from us the same working day.
2. **First assessment** — On the phone we clarify what has been checked and whether it looks like the link, the equipment or the configuration. Then we know which test equipment has to come.
3. **Appointment by urgency** — If operations have stopped, we try to come at short notice. For a partial fault we plan the appointment to fit your schedule.
4. **Measure, narrow down, fix** — On site we test the suspect links and fix what the measurement shows: a repair splice, a new link or corrected patching – a workaround first if needed.
5. **Report** — You get the test report of the restored link and a short statement of the cause. Payment is due after the visit.

## Frequently asked questions

### How quickly can you be there?

We reply to a fault report the same working day and book the appointment by urgency: if operations have stopped, we try to come at short notice. We do not offer a guaranteed response time that we could not keep every time – if we can’t make it that day, we say so straight away rather than keep you waiting.

### Is the fault ours or the provider’s?

If everything inside works – printers, servers, internal calls – and only the internet is down, it is usually the connection; then your provider’s fault line helps. If areas, floors or single devices on your own network fail, the fault is on your side. Where it is unclear, we test up to the handover point and tell you, with a measured value, which side it is on.

### Can you locate a cable break without tearing everything open?

On fibre, yes. The OTDR shows the distance along the fibre to the break. Because fibres lie in the cable with excess length and there are slack loops, we match the reading against the route plan and metre markings – so you only open up where the fault actually is.

### The link works sometimes – is that a cable fault too?

Often, yes. Intermittent outages point to a link right at the limit, for example a poorly terminated connector or too tight a bend. Certification shows it, while a simple continuity test reports such links as fine.

### What does troubleshooting cost?

Troubleshooting is charged by time, because nobody knows beforehand how long narrowing down takes. We estimate the effort in the quote, state travel up front and get in touch before the effort exceeds our estimate.

### Do you work on installations someone else built?

That is the normal case. We test the installation as we find it and tell you what we find – even if the cause is workmanship we were not responsible for.

### And if the fault is not in the cabling at all?

Then we say so. Often it is a configuration, an overloaded uplink or a faulty port. We narrow it down as far as our area goes and name the rest clearly, so you don’t keep going round in circles.

### Can we work with you in English?

Yes. You can reach us and work with us in English or German.

### How do we pay?

After the visit, by SEPA bank transfer, invoice or PayPal.

## Standards and sources

- [Borzycki, Gajewski: OTDR distance and cable length, JTiT 4/2021](https://jtit.pl/jtit/article/view/485)
- EN 50173-1 – classes and limits for copper and fibre links

## Contact

Email: info@utechit.de
Phone: +49 30 50930365


---

## Provider

UltraTech Germany, Leipziger Straße 40, 10117 Berlin
Email: info@utechit.de · Phone: +49 30 50930365 (WhatsApp)
More: https://utechit.de/llms.txt · MCP: https://utechit.de/api/ucp/mcp