> We plan and set up access control systems for businesses anywhere in Germany: readers at the doors, controllers on their own network segment, encrypted fobs or cards, and access rights by role and time. You receive documentation of doors, rights and log retention that you can hand to your works council and data protection officer.

URL: https://utechit.de/business/access-control
Alternate language version: https://utechit.de/de/business/zutrittskontrolle
Language: en
Provider: UltraTech Germany, Leipziger Straße 40, 10117 Berlin
Service area: Deutschland

An access control system replaces the bunch of keys – and creates a record every time a door opens: who, where, when. Many installations ignore that. A reader goes up, the logs grow without limit, and nobody has decided who may read them. Add fobs that can be copied in seconds and readers that send their data to the controller unencrypted. We build the system so that the technology matches the purpose you define: encrypted credentials, rights by role, retention periods set. We do not give the legal assessment – we provide the technical conditions and the documentation for it.

## Key figures

- **§ 87 BetrVG** — Works-council co-determination on technical monitoring
- **Art. 5 GDPR** — Purpose and storage limitation
- **ASR A2.3** — Escape routes stay openable

## What businesses use access control for

- **Office instead of a bunch of keys** — Block a lost card instead of replacing the lock system; change rights without anyone handing back a key.
- **Server room and technical rooms** — Authorised people only, every opening logged – wired online so a block takes effect at once.
- **Storage and goods-in** — Time profiles for shifts and suppliers, separate areas for storage and office.
- **Several tenants in one building** — Shared entrance, separate floors: each tenant manages only their own credentials.
- **Modernise an existing system** — Replace 125 kHz credentials, move controllers onto their own network, block orphaned users, set a retention period.
- **For electrical and security contractors** — You provide routes and power, we take care of network, controllers and set-up.

## What we deliver

- Site survey: doors, entrances and areas, and which door needs which solution
- Planning with you: areas, roles, time profiles – who may go where, and when
- Mounting readers and, depending on the door, electronic cylinders or fittings
- Controllers connected on their own VLAN, separate from the office network
- Encrypted credentials (e.g. MIFARE DESFire) instead of copyable 125 kHz fobs
- Encrypted link between reader and controller where the system supports it (OSDP Secure Channel)
- Roles, time profiles and admin accounts with graded rights
- Retention period for access logs, with automatic deletion
- Handover documentation: doors, components, roles, rights, retention periods

## From credential to log

An access control system is a chain. If one link is weak, the best reader is no help:

1. **Credential** — Fob or card with current encryption
2. **Reader** — At the door, encrypted to the controller where supported
3. **Controller** — Decides on rights, on its own VLAN
4. **Lock** — Door strike, motor lock or cylinder; power from your electrician
5. **Software** — Roles, time profiles, logs with retention

The most common weaknesses are copyable 125 kHz credentials and the unencrypted Wiegand line between reader and controller. We avoid both in new systems.

## Which credential?

The credential decides how easily access can be copied:

| Credential | Encryption | Assessment |
| --- | --- | --- |
| 125 kHz fob | None | Copyable with simple devices; unsuitable for new systems |
| MIFARE Classic (13.56 MHz) | Crypto1, considered broken | Existing systems only |
| MIFARE DESFire EV2 / EV3 (13.56 MHz) | AES | State of the art for new systems |
| Smartphone (BLE / NFC) | Depends on the system | Possible where supported; plan a fallback credential |

Which credentials are possible depends on the system. For existing systems we check whether a change is possible without new readers.

## What we deliver – and what you settle legally

The technology and the documents come from us. The legal assessment stays with you and your data protection officer:

**Our documentation**

- Door list with components
- Roles, time profiles and rights
- Log retention period
- Admin accounts

**Your side**

- Define purpose and retention (Art. 5 GDPR)
- Involve the works council if there is one (§ 87(1) no. 6 BetrVG)
- Entry in the record of processing activities
- Inform staff (Art. 13 GDPR)

If the system is also to record working time, that is a separate purpose with its own basis. We then keep access and time data apart from the set-up onwards.

## What you get at handover

- Door list with reader, controller and locking per door
- Roles and rights concept with time profiles
- Documentation of log retention and admin accounts
- Briefing: issuing, blocking and changing credentials

## What does access control cost?

You receive a quote after the site survey. It lists:

- **Planning, mounting, network, set-up:** In the quote after the survey
- **Readers, controllers, cylinders, credentials:** Itemised
- **Travel:** Stated in advance

What drives the price:

- Number of doors, online or offline
- Number of users and credentials
- Cable routes and existing network
- Escape or fire doors
- Taking over an existing system
- Travel

 Payment after installation and handover: SEPA bank transfer, invoice or PayPal.

## For an accurate quote

A floor plan with the doors to be secured helps most.

- Which doors – ideally marked on a floor plan
- Which of them are on escape routes or are fire doors
- How many people get a credential
- Roles and times you want (e.g. shifts, cleaning, suppliers)
- Existing system: manufacturer, credentials, age
- Whether there is a works council
- Whether working time should be recorded too
- Preferred date

## How a job runs

1. **Site survey** — We walk the doors: entrances, server room, storage, offices. For each door we check whether it is on an escape route, whether it is a fire door, and where power and network are available.
2. **Rights concept and quote** — Together you decide which roles exist and who may go where, and when. You receive the door list, the rights concept and a quote – the concept also serves as a basis for agreeing the system with the works council.
3. **Mounting and cabling** — Readers, controllers and locks are fitted and the data cables pulled. Fixed mains connections are made by your qualified electrician; we agree the interface beforehand.
4. **Set-up** — Controllers on their own VLAN, roles and time profiles created, credentials enrolled, log retention set, admin accounts with graded rights.
5. **Test, briefing and handover** — Every door is tested with authorised and blocked credentials. We show you how to issue and block credentials and hand over the documentation. You pay after the handover.

## Frequently asked questions

### What does access control cost?

You receive a quote after the site survey. It depends on the number of doors, whether a door is wired (online) or fitted with a battery-powered cylinder (offline), the number of users and credentials, and the cable routes. Devices and materials are itemised.

### Does the works council have to agree?

If your company has one: yes. An access control system stores who opened which door and when, which makes it a technical device suited to monitoring behaviour or performance under § 87(1) no. 6 of the German Works Constitution Act (BetrVG). Whether you intend to monitor anyone does not matter. Settle this before installation; our rights concept can serve as a basis for the works agreement.

### How long may access logs be kept?

There is no fixed statutory period. The GDPR requires data to be kept only as long as its purpose needs (Art. 5(1)(e)). You set the purpose and the period, ideally with your data protection officer. We configure the period, and the system deletes automatically after it.

### Can the access system also record working time?

Often technically yes, but it is a second purpose: access data serve security, time records serve working time. Under the GDPR principle of purpose limitation (Art. 5(1)(b)) each use needs its own basis, access rights and retention. If you want both, we set them up separately from the start.

### Are old 125 kHz fobs still secure?

No. 125 kHz fobs send their ID without encryption and can be copied with cheap devices. MIFARE Classic encryption is also considered broken. For new systems we use credentials with current encryption, such as MIFARE DESFire EV2 or EV3.

### What is the difference between online and offline doors?

Online doors are wired to the controller: rights and blocks apply at once and every opening is logged. Offline doors have battery-powered cylinders or fittings with no cable; rights are carried by the credential or a programming device. Offline is cheaper to retrofit, online reacts faster – most sites combine both: entrances and server room online, offices offline.

### What about escape doors and fire doors?

Doors on escape routes must open in the direction of escape at all times (German workplace rule ASR A2.3) – access control must not prevent that. On fire and smoke doors only components permitted by the door’s approval may be used. We identify such doors during the survey and involve the manufacturer or the person responsible for fire safety before we quote.

### Do you do the electrical installation?

No. We install readers, controllers and data cabling; fixed mains connections are made by your qualified electrician. We agree beforehand where each connection is needed.

### Can you take over an existing system?

Often, yes. Typical tasks: replacing old 125 kHz credentials with encrypted ones, moving controllers onto their own network, blocking orphaned users and credentials, setting a retention period and documenting the system. Whether that works with the existing system is checked during the survey.

## Standards and sources

- [§ 87(1) no. 6 German Works Constitution Act (BetrVG)](https://www.gesetze-im-internet.de/betrvg/__87.html)
- [Art. 5 GDPR – principles of processing](https://eur-lex.europa.eu/eli/reg/2016/679/oj)
- ASR A2.3 – escape routes and emergency exits (German workplace rule)

## Contact

Email: info@utechit.de
Phone: +49 30 50930365


---

## Provider

UltraTech Germany, Leipziger Straße 40, 10117 Berlin
Email: info@utechit.de · Phone: +49 30 50930365 (WhatsApp)
More: https://utechit.de/llms.txt · MCP: https://utechit.de/api/ucp/mcp